This document contains two groups of papers. In the first, the papers
are actually on-line to be browsed and there is also usually access to
the postscript and pdf versions of the paper. In the second section, access is
given just to postscript or pdf versions of the paper.
This site does not contain all IRS publications. A more complete
listing in pdf format is here.
As well as the papers listed below, there are several
other related IRS WWW-sites which may be of interest.
They can all be accessed via
http://www.irs.inms.nrc.ca/inms/irs/irs.html.
Papers available on-line and as postscript and in some cases as pdf
-
Iwan Kawrakow
On the effective point of measurement in megavoltage photon beams
Med.Phys. (in press)
Discusses the effective point of measurement (EPOM) for thimble chambers
in megavoltage photon beams. Based on the results of Monte Carlo
simulations, its is shown that the EPOM depends on every detail of the
chamber geometry and is generally different from the recommended
upstream shift of 0.6 times cavity radius.
-
Iwan Kawrakow
On the efficiency of photon beam treatment head simulations
Medical Physics 32 (2005) 2320-2326
Provides a theoretical explanation of the efficiency of photon beam
treatment head simulations using various forms of bremsstrahlung
splitting and gives a convenient recipe for determining the optimum
splitting number.
- Elena Tonkopi, M. R. McEwen, B. R. B. Walters and Iwan Kawrakow
Influence of ion chamber response on
in-air profile measurements in megavoltage photon beams
Medical Physics 32 (2005) 2918-2927.
Shows that plastic mini-phantoms are better for measuring in air
profiles of megavoltage photon beams and that one has to take into
account the variation of detector response with distance from the
central axis when comparing measurements to Monte Carlo simulation results.
- Ernesto Mainegra-Hing, D. W. O. Rogers and Iwan Kawrakow
Calculation of photon energy deposition kernels and electron dose point kernels in water.
Medical Physics 32 (2005) 685-699.
Presents energy deposition kernels calculations with EGSnrc
and investigates differences to previous EGS4 results.
-
I. Kawrakow, D. W. O. Rogers and B. Walters
Large efficiency improvements in BEAMnrc
using directional bremsstrahlung splitting
Medical Physics 31 (2004) 2883-2898.
Describes a new variance reduction technique, called DBS and
implemented in BEAMnrc, that increases the
efficiency of photon beam treatment head simulations by up to a factor
of 8 compared to SBS, the best technique for such simulations
previously avaiable.
-
I. Kawrakow
The effect of Monte Carlo statistical uncertainties
on the evaluation of dose distributions in radiation treatment
planning
Phys. Med. Biol. 49 (2004) 1549 - 1556
The paper presents a mathematical derivation of the probability distribution
to calculate a certain value of a cost function given a Monte Carlo
simulation of a dose distribution and draws various interesting
conclusions.
- Ernesto Mainegra-Hing, Iwan Kawrakow and D. W. O. Rogers
Calculations for plane-parallel ion chambers
in 60Co beams using the EGSnrc Monte Carlo code.
Medical Physics 30 (2003) 179 - 189.
- N. I. Kalach and D. W. O. Rogers
Which accelerator photon beams are `clinic-like' for reference dosimetry
purposes
Medical Physics 30 (2003) 1546 -- 1555.
Investigation of how well TPR20,10 behaves as a beam quality
specifier in clinical and non-clinical beams and gives a criterion for
when it is acceptable in non-clinical beams in terms of a relationship
between TPR20,10 and %dd(10)x.
- L. A. Buckley, I. Kawrakow and D. W. O. Rogers
An EGSnrc investigation of cavity theory for ion chambers measuring air
kerma
Medical Physics 30 (2003) 1211 -- 1218.
Outlines detailed comparison of EGSnrc calculations to measured
responses of aluminum and graphite thimble chambers and demonstrates the
sensitivity of the results to cross sections used in the calculations.
-
I. Kawrakow
On the de-noising of Monte Carlo calculated dose
distributions
Phys. Med. Biol. 47 (2002) 3087 - 3104.
This paper describes a smoothing algorithm for de-noising
Monte Carlo calculated dose distribution in radaition treatment planning
and introduces 5 criteria for evaluating the performence of smoothing
algorithms.
- B.R.B. Walters, I. Kawrakow and D. W. O. Rogers
History by history statistical estimators in the BEAM code system
Medical Physics 29 (2002) 2745 - 2752.
Outlines the history by history method of statistical analysis as
applied in the BEAMnrc code system and later applied to all the NRC
RZ-user codes. This method improves the uncertainty estimates
considerably.
- D. W. O. Rogers
Monte Carlo
Techniques in Radiotherapy
Physics in Canada (2002) Vol.58 #2, pp 63-70
Paper written for a special issue of Physics in Canada devoted to
Medical Physics in Canada. The paper outlines how Monte Carlo
techniques are used to simulate radiation transport and describes various
applications related to radiation standards and radiotherapy dosimetry.
- D. W. O. Rogers
Review of ICRU Report 64: Dosimetry of high-energy photon beams based on
standards of absorbed dose to water
Physics in Medicine and Biology Vol 47 (2002) 3663 - 3665
An invited book review of the ICRU's Report 64 on absorbed dose
standards.
- Daryoush Sheikh-Bagheri and D. W. O. Rogers
Calculation of nine megavoltage photon beam spectra using
the BEAM Monte Carlo code
Medical Physics 29 (2002) 391 - 402
The calculated spectra and other information from 9 clinical photon beams.
- Daryoush Sheikh-Bagheri and D. W. O. Rogers
Sensitivity of megavoltage photon beam Monte Carlo simulations to
electron beam and other parameters
Medical Physics 29 (2002) 379 - 390
A study of what parameters are important when simulating photon beams
from clinical accelerators.
- Jan P. Seuntjens, C. K. Ross, K.R. Shortt and D. W. O. Rogers
Absorbed-dose
beam quality conversion factors for cylindrical chambers in high-energy
photon beams
Medical Physics 27 (2000) 2763 -- 2779
Presents a detailed comparison of measured kQ factors for 6
ion chambers to the calculated values in TG-51 and elsewhere.
-
I. Kawrakow
VMC++, electron and photon Monte Carlo calculations optimized
for Radiation Treatment Planning
Published in Advanced Monte Carlo for Radiation Physics, Particle
Transport Simulation and Applications: Proceedings of the
Monte Carlo 2000 Meeting Lisbon, A. Kling et al (edts.),
Springer, Berlin, 2001, pp 229-236.
Main VMC++ reference so far.
-
I. Kawrakow and M. Fippel
Investigation of variance reduction techniques for
Monte Carlo photon dose calculation using XVMC
Phys. Med. Biol. 45 (2000) 2163 - 2184.
Introduces the most efficient Monte Carlo simulation technique known todate
for photon beam dose calculations in radiation treatment planning.
- Daryoush Sheikh-Bagheri, D. W. O. Rogers, Carl K. Ross and
Jan P. Seuntjens
Comparison of measured and Monte
Carlo calculated dose distributions from the NRC linac
Medical Physics 27 (2000) 2256 -- 2266
Presents a detailed comparison of measured and calculated dose
distributions in two NRC accelerator photon beams. Complete
specification of the accelerator is included.
- I. Kawrakow
``Accurate condensed history Monte Carlo simulation of electron transport''
Part I: ``EGSnrc, the new EGS4 version'', Med. Phys. 27 (2000)
485-498.
Describes the implementation of various aspects of the condensed history
technique into EGSnrc. These include an improved electron-step
algorithm, an exact boundary crossing algorithm (these two became known
as PRESTA-II), energy loss evaluation, fictitious cross section method
and multiple elastic scattering.
Part II: ``Application to ion chamber response simulations'',
Med. Phys. 27 (2000) 499-513.
Discusses various artifacts due to the inaccurate implementation
of the condensed history technique and gives analytical expressions
for their effect on the simulated cavity dose. Demonstrates that
EGSnrc is capable of performing artifact-free simulations on the
0.1% level.
These two papers from the basis of the improved electron transport
implementation in the
EGSnrc package compared to EGS4.
- I. Kawrakow and A.F.Bielajew
``On the condensed history technique for electron transport''
Nucl. Instr. Meth. B142 (1998) 253 - 280.
Extensive discussion of various condensed history algorithms
and construction of a new electron-step algorithm that has
an order of magnitude smaller truncation error.
- I. Kawrakow and A.F.Bielajew
``On the representation of electron multiple elastic-scattering
distributions for Monte Carlo calculations''
Nucl. Instr. Meth. B134 (1998) 325 - 336.
Presents an exact, any angle, multiple elastic scattering theory that
results from the screened Rutherford cross section.
-
D.W.O. Rogers, B.A. Faddegon, G.X. Ding, C.-M. Ma, J. Wei and T.R.
Mackie,
``BEAM: A Monte Carlo code to simulate radiotherapy
treatment units,''
Med. Phys. 22 (1995) 503 - 524.
Extensive paper describing a large code system.
See also the BEAM home page
- D.W.O. Rogers and Radhe Mohan
Questions for comparison of clinical Monte Carlo codes
Paper from XIII-th International Conference on the Use of Computers in
Radiotherapy, Heidelberg, May 2000
Presents a series of benchmark questions along with the data (in a digital
format) needed to answer them.
- D.W.O. Rogers
Fundamentals of Dosimetry based on Absorbed-Dose
Standards
Chapter in ``Teletherapy: Present and Future'' edited by J. R. Palta and
T. R. Mackie, pages 319 - 356 (AAPM, Washington DC, 1996).
Discusses some of fundamentals regarding AAPM's new TG-51 clinical dosimetry
protocol which is still under development.
-
D.W.O. Rogers
A new approach to electron beam reference dosimetry
Medical Physics, Vol 25(#3) (1998) 310 - 320
Paper suggests an approach based on
cm
and absorbed dose calibration factors. It provides values of all
necessary parameters, including a newly calculated set of
values for plane-parallel chambers in water.
-
D. W. O. Rogers
Correcting for electron contamination
at dose maximum in photon beams
Med.Phys. 26 (1999) 533 - 537
Short paper which provides a correction for electron contamination in
photon beams when a 1mm lead foil is placed in the beam. The original
purpose was to allow the lead foil to be at 30 cm from the phantom but
paper also corrects some mistakes found in the earlier paper by Li
and Rogers on the same subject.
-
D. W. O. Rogers and C.L. Yang
Corrected relationship between
%dd(10)x and stopping-power ratios
Med.Phys. 26 (1999) 538 -- 540
Paper presents the relationship between %dd(10)x and
stopping-power ratios needed in TG-51. In an earlier paper a simple
1/r2 correction to parallel beam depth-dose curves was used
(Kosunen and Rogers, 1999), but in this paper a more accurate
relationship is used.
-
G. M. Mora, A. Maio, and D. W. O. Rogers
Monte
Carlo Simulation of a Typical 60Co Therapy Source
Med.Phys. 26 (1999) 2494-2502
Using BEAM, a typical 60Co unit is modelled in detail. The results
predict the variation in air-kerma output with field size within 0.1%
and for the first time show excellent agreement in the buildup region
of the depth-dose curves.
- J. Borg and D. W. O. Rogers
Spectra and air-kerma strength for encapsulated 192Ir
sources
Medical Physics 26 (1999) 2441-2444.
Calculated spectra and air-kerma strengths per unit activity for various
types of 192Ir sources.
- J. Borg, I. Kawrakow, D. W. O. Rogers and J.P. Seuntjens
Monte Carlo study of Spencer Attix cavity theory at low photon energies
Submitted to Medical Physics, August 1999 .
Using EGSnrc it is demonstrated that Spencer-Attix cavity theory works
well for graphite-walled cavity chambers for 192-Ir sources. It is found
that the insulators in the NRC primary standard for air kerma play a
much more important role than appreciated previously.
- G.G. Zhang, D.W.O. Rogers, J.E. Cygler and T.R. Mackie
Corrections for Electron Beam Relative Output Factors
Due to Changes in
and Field Size
Investigation of the corrections needed to electron beam ROFs measured
with ion chambers.
- G.G. Zhang, D.W.O. Rogers, J.E. Cygler and T.R. Mackie
Monte Carlo
Investigation of Electron Beam Output Factors vs Size of Square Cutout
Demonstrates the ability of BEAM to measure cutout factors for square inserts within
about 1% at SSD=100 and SSD=115 cm.
- C.-M. Ma, B.A. Faddegon, D.W.O. Rogers, and T.R. Mackie
Accurate Characterization of Monte-Carlo Calculated
Electron beams for Radiotherapy
Med. Phys. 24 (1997) 401 - 416.
Discusses use of beam characterization models to accurately represent
and reconstruct phase space data from BEAM simulations. It saves
computer disk space and considerable time in the beam simulation for
symmetric fields.
- G.X. Ding, D.W.O. Rogers, J.E. Cygler and T.R. Mackie
Electron fluence correction factors for conversion of
dose in plastic to dose in water
Med. Phys. 24 (1997) 161 - 176.
Calculates the factors using BEAM calculated realistic electron beams.
Paper includes an extensive discussion of the theory of these factors
and proposes a more rigorous approach along with simple summaries of the
data for practical application.
- D.T. Burns, G.X. Ding and D.W.O. Rogers
as a beam quality specifier for
selecting stopping-power ratios and reference depths for electron dosimetry
Medical Physics 23 (1996) 383 - 388
Paper proposing new depth for reference dosimetry in electron
beams.
- G.X. Ding, D.W.O. Rogers and T.R. Mackie
Mean energy, energy-range relationships and
depth-scaling factors for clinical electron beams
Med. Phys. 23 (1996) 361 - 376.
Studies relationships between energy and range using realistic beams
simulated using the BEAM code. Also presents depth-scaling factors for
various plastic phantoms.
- G.X. Ding, D.W.O. Rogers and T.R. Mackie
Calculation of Stopping-Power Ratios Using Realistic Clinical
Electron Beams
Med. Phys. 22 (1995) 489 - 501.
Reports correction factors for electron beam dosimetry needed to account
for realistic instead of mono-energetic calculations of sprs.
- X.A. Li and D.W.O. Rogers
Electron Mass Scattering Powers: Monte Carlo and
Analytical Calculations
Med. Phys. 22 (1995) 531 - 541.
Comparison of calculations with Moliere multiple scattering theory and
those of Rossi used by the ICRU. Results show that ICRU values
underestimate the mass scattering power for low-Z materials, but more
importantly, the Gaussian models using the msp are inappropriate.
- D.W.O. Rogers
Ionizing Radiation Dosimetry and Medical
Physics
Physics in Canada, 51 (1995) 178 - 181.
Review paper for Physics in Canada issue commemorating 100 years of use
of ionizing radiation in medicine.
- D. W. O. Rogers and C. K. Ross and K. R. Shortt and N. V. Klassen
and A. F. Bielajew
Towards a Dosimetry System Based on Absorbed-Dose
Standards
Proc. of Symp. on Meas. Assurance in Dosimetry, (IAEA, Vienna, 1994)
565 - 580.
Invited review arguing for a new approach to clinical dosimetry and
presenting various projects at NRC.
- X. A. Li and D. W. O. Rogers
Reducing Electron Contamination for Photon-Beam-Quality
Specification
Med. Phys. 21 (1994) 791 - 798
Calculates factors which correct for the effects of electron
contamination in radiotherapy beams on measured % depth dose at 10 cm.
- A. Kosunen and D. W. O. Rogers
Beam Quality Specification for Photon Beam
Dosimetry
Med. Phys. 20 (1993) 1181 - 1188.
Argues that using %dd(10), the percentage depth dose at 10 cm in a
10
10 cm
field is a better photon beam quality specifier
than
.
NRC Reports
-
D. W. O. Rogers and J. McCaffrey
The
2003 revision of the NRC standard for
air-kerma in a 60Co beam
NRC Report PIRS-876 (Ottawa, 2003)
Summarizes changes to the primary standard for air kerma in a
60Co beam.
-
D.W.O. Rogers, I. Kawrakow, N.V. Klassen, J. P. McCaffrey, M.R. McEwen,
P.R.P. Saull, C.K. Ross and G. Zeng
NRC Activities and Publications, 2001-2003: Report to CCRI(I) Meeting, BIPM
The IRS groups biannual report to the BIPM's Consultatitive Committee on
Ionizing Radiation Standards.
- J.R. Treurniet and D.W.O. Rogers
EGS_Windows_4.0 User's Manual
Manual for a 3-D tool for displaying the geometry and tracks of an EGS
simulation. This version works on any X-Window platform.
- D.W.O. Rogers
NRC Bibliography of EGS Related Papers
Automated bibliography of EGS4 papers on NRC/IRS data base. Updated
occasionally.
- D.W.O. Rogers
NRC Bibliography of OMEGA/BEAM Related Papers
Automated bibliography of papers about BEAM or the OMEGA project. Updated
occasionally.
-
D.W.O. Rogers, I. Kawrakow, N.V. Klassen, J. P. McCaffrey,
C.K. Ross, K.R. Shortt, L. van der Zwan, and G. Daskalov
NRC Activities and Publications, 1999-2001: Report to CCRI(I) Meeting, BIPM
The IRS groups biannual report to the BIPM's Consultatitive Committee on
Ionizing Radiation Standards . It includes a complete list of
publications for the 2 years.
-
D.W.O. Rogers, I. Kawrakow, N.V. Klassen, C.K. Ross,
J.P. Seuntjens, K.R. Shortt, L. van der Zwan, Jette Borg and G Daskalov
NRC Activities and Publications, 1997-1999: Report to CCRI(I) Meeting, BIPM
The IRS groups biannual report to the BIPM's Consultatitive Committee on
Ionizing Radiation Standards . It includes a complete list of
publications for the 2 years.
- D. W. O. Rogers and J. Treurniet
Monte Carlo calculated wall and axial non-uniformity corrections for
primary standards of air kerma
NRC Report PIRS 663 (Ottawa, May 1999).
Report which demonstrates the difference between Monte carlo calculated
correction factors and those found by other techniques. It demonstrates
the ability of the calculations to reproduce experimental results.
- J. Borg and D. W. O. Rogers
Monte Carlo Calculations of Photon Spectra in Air from 192Ir
Sources
NRC Report PIRS 629r (Ottawa, March 1999).
Calculated spectra and air-kerma strengths per unit activity for various
types of 192Ir sources.
-
D.W.O. Rogers, A.F. Bielajew, N.V. Klassen, C.K. Ross,
J.P. Seuntjens, K.R. Shortt and L. van der Zwan
NRC Activities and Publications, 1995-1997:
Report to CCEMRI(I) Meeting, BIPM
The IRS groups biannual report to the Consultatitive Committee on
Ionizing Radiation Standards of the BIPM. It includes a complete list of
publications for the 2 years.
- G.X. Ding and D.W.O. Rogers
Energy spectra, angular spread, and dose
distributions of electron beams from various accelerators used in
radiotherapy
NRC Report PIRS 439 (Ottawa, April 1995).
Extensive tables and graphs of data calculated with BEAM.
- A. Booth and D.W.O. Rogers
Monte Carlo Study of Effects of Phantom Size, Radial
Position, and Depth on Photon Beam Calibration
NRC Report PIRS-507, Aug 1995
Reports detailed Monte Carlo study of stopping-power ratios and to a
lesser extent dose in cylindrical water phantoms of various sizes.
- D.W.O. Rogers
Spencer-Attix water to air mass collision
stopping power ratios as a function of depth and beam quality,
R50
NRC Report PIRS-719, June, 2000
Presents tables of stopping-power ratios vs depth and R50 as
calculated using the Burns et al general function and also compares the
results with the original database of stopping-power ratios for
realistic electron beams as calculated by Ding et al.
Papers and Reports available as postscript and/or as pdf
Note, in this section, depending on your browser, you may have to
download the compressed versions separately, uncompress or gunzip them
and then view them.
NRC Papers
- D. W. O. Rogers
Monte Carlo techniques for primary standards of ionizing
radiation and for dosimetry protocols
MC2000 Conference Proceedings, p291-298
pdf 464 kbyte
- I. Kawrakow and D. W. O. Rogers
The EGSnrc System, a status report
MC2000 Conference Proceedings, p135-140
pdf 376 kbyte
- I. Kawrakow
VMC++, electron and photon Monte Carlo calculations
optimized for Radiation Treatment Planning
MC2000 Conference Proceedings, p229-236
pdf 441 kbyte
- M. Fippel, M. Alber, M. Birkner, W. Laub,
F. Nusslin and I. Kawrakow
Inverse treatment planning for radiation therapy based on fast
Monte Carlo dose calculation
MC2000 Conference Proceedings, p217-222
pdf 856 kbyte
- Alex F Bielajew and D. W. O. Rogers
A standard timing benchmark for EGS4 Monte Carlo calculations
Medical Physics 19 (1992) 303 -- 304
(postscript 360 Kb)
(compressed postscript 84 Kb)
(gzip postscript 66 Kb)
(pdf 144 Kb)
- Alex F Bielajew
Monte Carlo modeling in external electron-beam radiotherapy--Why leave
it to chance?
(postscript version 2.2 Mb)
(compressed postscript version 336 Kb)
(gzip postscript version 245 Kb)
- Alex F Bielajew
Plural and multiple small-angle scattering from a screened Rutherford
cross section
Nuclear Instruments and Methods, B86 (1994) 257 - 269
(postscript version 3.6 Mb)
(compressed postscript version 749 Kb)
(gzip postscript version 334 Kb)
- Alex F Bielajew
The effect of strong longitudinal magnetic fields on dose deposition
from electron and photon beams
Med. Phys. 20 (1993) 1171 - 1179
(postscript version 1.3 Mb)
(compressed postscript version 205 Kb)
(gzip postscript version 136 Kb)
- Alex F Bielajew, Ruqing Wang, and Simon Duane
Incorporation of single elastic scattering in the EGS4 Monte Carlo code
system: Tests of Moliere theory
Nuclear Instruments and Methods, B82 (1993) 503 - 512
Partial-wave cross sections and single Rutherford scattering in EGS
(postscript version 1.3 Mb)
(compressed postscript version 450 Kb)
(gzip postscript version 334 Kb)
- Alex F Bielajew
A hybrid multiple-scattering method
Nuclear Instruments and Methods, in press 30-Oct-95
(postscript version 2.1 Mb)
(compressed postscript version 559 Kb)
(gzip postscript version 360 Kb)
NRC Reports
- Alex F Bielajew, H. Hirayama, W.R. Nelson and D.W.O. Rogers
History, overview and recent improvements of EGS4
Report NRCC/PIRS-0436, June 1994
(postscript version 729 Kb)
(compressed postscript version 194 Kb)
(gzip postscript version 152 Kb)
( pdf version 342 Kb)
- Alex F Bielajew, Rahde Mohan, and Chen-Shou Chui
Improved bremsstrahlung photon angular sampling in the EGS4 code system
Report NRCC/PIRS-0203, Nov. 1989
(postscript version 340 Kb)
(compressed postscript version 132 Kb)
(gzip postscript version 99 Kb)
- Alex F Bielajew and Paul E Wiebe
EGS_Windows--A Graphical Interface to EGS
Report NRCC/PIRS-0274 1991
(postscript version 241 Kb)
(compressed postscript version 91 Kb)
(gzip postscript version 68 Kb)
This is the manual for EGS_Windows Version 1
- Alex F Bielajew
Graphics!
Report NRCC/PIRS-397 1993
(postscript version
334 Kb)
(compressed postscript version 75 Kb)
(gzip postscript version 59 Kb)
Summarizes the history of various gaphics packages for EGS
- Alex F Bielajew
Improved angular sampling for pair production in the EGS4 code system
Report NRCC/PIRS-0287R, 1994
(postscript version 478 Kb)
(compressed postscript version 181 Kb)
(gzip postscript version 141 Kb)
- Alex F Bielajew
HOWFAR and HOWNEAR: Geometry Modeling for Monte Carlo Particle
Transport
Report NRCC/PIRS-0341, 1995
(postscript version 4.4 Mb)
(compressed postscript version 614 Kb)
(gzip postscript version 317 Kb)
(pdf version 627 Kb)
- Keath R Borg and Alex F Bielajew
QUADPLOT: A programme to plot quadric surfaces
Report NRCC/PIRS-0491, 1995
(postscript version 4.2 Mb)
(compressed postscript version 661 Kb)
(gzip postscript version 412 Kb)
- W.R. Nelson, A.F. Bielajew, D.W.O. Rogers and H. Hirayama
EGS4 in '94: A decade of enhancements
SLAC Report SLAC-PUB-6625 1994
These are the slides used by Ralph Nelson in an invited talk at the
World Congress on Medical Physics in Rio, Aug 1994 (in landscape
orientation)
(postscript version 2.0 Mb)
(compress postscript version 286 Kb)
(gzip postscript version 213 Kb)
- A.F. Bielajew
EGS4 timing Comparisons
Regularly updated results of the EGS4 timing benchmark
(postscript version 69 kb)
(compressed postscript version 30 Kb)
(gzip postscript version 21 Kb)
-
The IRS Thermoluminescent Dosimetry System
I. Janovsky and C. K. Ross
Report NRCC/PIRS-0369, 1993
(pdf version)
(draft)
(test)
-
The 2003 revision of the NRC standard for air-kerma in a Co-60 beam
D.W.O. Rogers and John McCaffrey
Report NRCC/PIRS-0876, 2003
(pdf version)
-
High Sensitivity Lithium Fluoride As a Detector for Environmental Dosimetry (M.Sc. Thesis)
S. D. Davis
Report NRCC/PIRS-0832, 2003
(pdf version)
-
The IRS Fricke Dosimetry System
A. Olszanski, N. V. Klassen, C. K. Ross and K. R. Shortt
Report NRCC/PIRS-0815, 2002
(pdf version)
-
Accurate Measurements of the Collision Stopping Powers for 5 to 30 MeV Electrons (Ph.D. Thesis)
Miller S. MacPherson
Report NRCC/PIRS-0626, 1998
(pdf version)
-
A Magnetic Spectrometer for Electron Energy Calibration
M. S. MacPherson and C. K. Ross
Report NRCC/PIRS-0617, 1998
(pdf version)
-
A Status Report on the NRC Sealed Water Calorimeter
J. P. Seuntjens, C. K. Ross, N. V. Klassen and K. R. Shortt
Report NRCC/PIRS-0584, 1999
(pdf version)